SYMPTOM | CAUSE | SOLUTION |
Gun does not actuate when triggered. | Air switch assembly is closed | Open |
Plugged exhaust | Clean air ports in handle | |
Damaged trigger spool o-rings | Replace | |
SYMPTOM | CAUSE | SOLUTION |
There is no fluid spraying when the gun is fully actuated. | Closed fluid valves | Open |
Plugged impingement ports | Clean | |
Plugged check valves | Clean | |
SYMPTOM | CAUSE | SOLUTION |
Gun actuates slowly. | Plugged exhaust | Clean air ports in handle |
Damaged piston o-rings | Replace | |
Dirty air valve, or damaged o-rings | Clean air valve or replace o-rings | |
SYMPTOM | CAUSE | SOLUTION |
There is a leakage between flat tip and mixing chamber. | Tip is not seated properly | Reassemble |
Damaged or missing seal | Replace | |
SYMPTOM | CAUSE | SOLUTION |
There is a pressure imbalance. | Plugged impingement ports | Clean |
Plugged check valves | Clean | |
Viscosities are not equal | Adjust temperature to compensate | |
SYMPTOM | CAUSE | SOLUTION |
There is A and/or B side fluid in the gun air section. | Damaged side seals | Replace |
Damaged mixing chamber | Replace | |
Damaged side seal o-rings | Replace | |
SYMPTOM | CAUSE | SOLUTION |
Fluid mist from mix chamber or air cap. | Damaged side seals | Replace |
Damaged mix chamber | Replace | |
Damaged side seal o-rings | Replace | |
SYMPTOM | CAUSE | SOLUTION |
The fluid does not shut off when fluid valves are closed. | Damaged fluid valves | Tighten packing or replace |
SYMPTOM | CAUSE | SOLUTION |
Burst of air from muffler when gun is triggered. | Normal | No action required |
SYMPTOM | CAUSE | SOLUTION |
Steady air leakage from muffler. | Damaged air valve o-rings | Replace |
Damaged piston o-rings | Replace |